9 Details on Servo Parameter Objects
9-34
G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
• In the same way as for Analog Monitor 1, analog signals of various monitors can be output from the
analog monitor connector on the front panel.
• Refer to the Analog Monitor 1 Selection (3416 hex) for the method to set this object.
• Set the output gain for analog monitor 2.
• Refer to the Analog Monitor 1 Scale Setting (3417 hex) for the method to set this object.
\
• Select the analog monitor output voltage direction.
• These are the output voltage range and the output direction when the Analog Monitor 1 Selection or
Analog Monitor 2 Selection is set to the Feedback Motor Speed, and the Analog Monitor 1 Scale
Setting or the Analog Monitor 2 Scale Setting is set to 0 (i.e., 1V = 500 r/min).
3418 hex
Analog Monitor 2 Selection
Setting range 0 to 21 Unit − Default setting 4 Data attribute A
Size 2 bytes (INT16) Access RW PDO map Not possible.
3419 hex
Analog Monitor 2 Scale Setting
Setting range 0 to
214748364
Unit − Default setting 0 Data attribute A
Size 4 bytes (INT32) Access RW PDO map Not possible.
3421 hex
Analog Monitor Output Selection
Setting range 0 to 2 Unit − Default setting 0 Data attribute A
Size 2 bytes (INT16) Access RW PDO map Not possible.