93
Frame Structure Section 6-2
Missing FINS-mini
Command
Response
The end code is 14 (format error).
Incomplete MRC and SRC Codes in FINS-mini
Command
The SRC is missing one character.
Response
The end code is 14 (format error).
Incomplete Node Address
Command
The node address is missing one character.
Response
None (There is no response because the return node address is unknown.)
Missing Subaddress, Invalid BCC
Command
Response
The subaddress is 00 and the end code is 13 (BCC error).
SID
0 1 0 0 0
Node No. Subaddress
BCC
STX ETX
0 1 0 0 1 4
Node No. Subaddress BCC
End code
STX
ETX
SID FINS-mini
0 1 0 0 0
MRC
0
Node No. Subaddress BCC
STX
ETX
0 1 0 0 1 4
Node No. Subaddress BCC
End code
STX
ETX
BCC
STX
ETX
0 1
Err
Node No.
BCC
STX
ETX
0 1 0 0 1 3
Node No. Subaddress BCC
End code
STX
ETX