Special Settings and Communications Settings Section 4-7
Send Wait Time: SWT (Send Wait Time)
The Send Wait Time Setting (SWT) will be displayed if the Up (SEL) Key ( )
is pressed from the Parity Setting Display (PTY).
(Returns to SWT display.)
s w
t
0
1 0
1
2
3
4
5
6
V
A
Yrs
s
°C
1
2
3
4
5
6
V
A
Yrs
s
°C
1
2
3
4
5
6
V
A
Yrs
s
°C
This parameter sets the RS-485 port's send wait time.
Press the Key to display the send wait time setting.
The setting can be changed by pressing the and
Keys.
The setting range is 0 to 999 ms.
Change the setting with the and Keys.
• If the or Key is pressed for more than 2 s, the SV
will change in 10-ms increments instead of 1-ms incre-
ments.
• The S8AS will automatically return to the SWT display if
no key is pressed within 3 s.
When the Key is pressed, the setting will flash. When
the flashing stops, the new setting will be saved and the
S8AS will return to SWT display.
• If you want to confirm the new setting, press the Key
again from the SWT display.
Switch to the
Reset
Method Set-
ting (RST).