4.5 Command Data Field
107
94H MECHATROLINK-II Data
Setting Warning 1
An incorrect parameter number was set in the command.
MECHATROLINK-II Data
Setting Warning 2
The command data is out of range.
MECHATROLINK-II Data
Setting Warning 4
Unmatched data size was detected.
95H MECHATROLINK-II Com-
mand Warning 1
A command was sent though the command sending conditions
were not satisfied.
MECHATROLINK-II Com-
mand Warning 2
An unsupported command was sent.
MECHATROLINK-II Com-
mand Warning 4
A command, especially latch command, interferes.
MECHATROLINK-II Com-
mand Warning 5
A sub command and main command interfere.
96H MECHATROLINK-II Com-
munications Warning
A communications error occurred during MECHATROLINK commu-
nications.
(cont’d)
Alarm
Display of
Response
Alarm Name Meaning
TOEP_C710806_03A_1_0.book Seite 107 Montag, 2. Juli 2007 3:55 15

Table of Contents