7.2 List of Parameters
130
Pn50A
Input Signal
Selection 1
2 2881H 8881H 2881H C
Pn50B
Input Signal
Selection 2
2 8883H 8888H 8883H C
(cont’d)
Param-
eter
No.
Name Data
Size
Min.
Set Value
Max.
Set Value
Units Factory Set-
ting
Valida-
tion
Refer-
ence
Page
1
Do not change.
n.
4th
digit
3rd
digit
2nd
digit
1st
digit
Reserved
8
Do not change.
Reserved
8
Do not change.
Reserved
2
8
Forward run enabled when CN1-4 input signal is
ON (L-level).
Always sets the signal to ON to enable forward run.
P-OT Signal Mapping
n.
4th
digit
3rd
digit
2nd
digit
1st
digit
8
Do not change.
Reserved
8
Do not change.
Reserved
8
Do not change.
Reserved
3
8
Reverse run enabled when C1-3 input signal is
ON (L-level).
Always sets the signal to ON to enable reverse run.
N-OT Signal Mapping