EasyManua.ls Logo

Omron SJDE-ANA-OY - Page 133

Omron SJDE-ANA-OY
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.2 List of Parameters
131
Pn515
Input Signal
Selection 5
2 8488H 8888H 8488H C
Pn522
Positioning
Completion
Width
4 0 1073741824 1 reference
unit
10 A 98
Pn524
NEAR Signal
Width
4 1 1073741824 1 reference
unit
100 A 100
Pn800
Communica-
tion Control
2 0000H 0F73H 0040H A
(cont’d)
Param-
eter
No.
Name Data
Size
Min.
Set Value
Max.
Set Value
Units Factory Set-
ting
Valida-
tion
Refer-
ence
Page
n.
4th
digit
3rd
digit
2nd
digit
1st
digit
8
Do not change.
Reserved
8
Do not change.
Reserved
8
Do not change.
Reserved
4
8
Emergency stop when C1-6 input signal is
OFF (H-level).
Always sets the signal to ON to disable
emergency stop.
E-STP Signal Mapping
n.
4th
digit
3rd
digit
2nd
digit
1st
digit
0
1
2
3
4
5
6
7
Normal status
Ignores data setting warning (A.94).
Ignores command warning (A.95).
Ignores both A.94 and A.95.
Ignores communications warning (A.960).
Ignores both A.94 and A.960.
Ignores both A.95 and A.960.
Ignores A.94, A.95, and A.960.
Warning Check Mask
0
Do not change.
Reserved
0
Do not change.
Reserved
0
Do not change.
Reserved
TOEP_C710806_03A_1_0.book Seite 131 Montag, 2. Juli 2007 3:55 15

Table of Contents

Related product manuals