7.2 List of Parameters
132
Pn801
Function
Selection
Application 6
(Software LS)
2 0000H 0103H — 0003H A
125
Pn803 Origin Range
2 0 250 1 reference
unit
10 A 97
Pn804 Forward Soft-
ware Limit
4 -1073741823 1073741823 1 reference
unit
1073741823 A 125
Pn806 Reverse Soft-
ware Limit
4 -1073741823 1073741823 1 reference
unit
-1073741823 A 125
Pn80B Linear
Acceleration
Constant
2 1 65535 10000 refer-
ence units/s
2
100 B 124
Pn80E Linear
Deceleration
Parameter
2 1 65535 10000 refer-
ence units/s
2
100 B 124
Pn814 Final Travel
Distance for
External Input
Positioning
4 -1073741823 1073741823 1 reference
unit
100 B 85
(cont’d)
Param-
eter
No.
Name Data
Size
Min.
Set Value
Max.
Set Value
Units Factory Set-
ting
Valida-
tion
Refer-
ence
Page
n.
4th
digit
3rd
digit
2nd
digit
1st
digit
0
1
2
3
Forward and reverse software limits enabled.
Forward software limit disabled.
Reverse software limit disabled.
Software limits disabled in both directions.
Software Limit Function
0
Do not change.
Reserved
0
Do not change.
Reserved
No software limit check using references
Software limit check using references
Software Limit Check Using References
0
1
TOEP_C710806_03A_1_0.book Seite 132 Montag, 2. Juli 2007 3:55 15