Status attributes Crocus CNV
106 Reference manual
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/ifSpeed
This attribute displays the current DTE interface speed in bits per second (bps), e.g. 640000. When the
DTE interface is down (ifOperStatus = down), the DTE interface speed is 0.
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/ifOperStatus
This attribute displays the current operational status of the DTE interface. The possible indications are:
Value Description
up
The DTE interface is up, data transfer is possible. In other words, there is a valid
connection between the DTE and the interface.
down
The DTE interface is down, data transfer is not possible. In other words, there is no
valid connection between the DTE and the interface. For example, because there is
no connection between DTE and the interface.
Remarks
In case of a Bridge interface, the ifSpeed attribute displays the speed on the LAN interface. In other
words, when a LAN is connected (i.e. ifOperStatus = up) then the ifSpeed is always 10240000 bps,
disregarding of the configuration attribute speed setting.
In case of a Router interface the ifSpeed and ifOperStatus attributes display the speed and operational
status between the Router interface and the Crocus CNV. This implies that as soon as you insert a
Router interface in the Crocus CNV then the crocusIfConv<2m/Nx64><Tt/Cv>/router/ifOperStatus value
becomes up, disregarding of the operational statuses on the Router interface itself. For that
information you have to connect to the Router interface.
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/ifClockingTx
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/ifClockingRx
These attributes display the clocking mode which is actually used by the Crocus CNV.
This is not necessarily the clocking mode you configured. It can be a clocking mode that is selected by
the Crocus CNV because it was not possible to select the clocking mode of your choice (for example,
because the external clock signal is lost).