Crocus CNV Status attributes
Reference manual 107
7.4.2 RS530, V35 and V36 interface status attributes
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/txdItu103
This attribute displays the status (on / off) of the transmit data signal (circuit 103). The txdItu103 attribute
only indicates the presence of the TxD signal, it does not monitor the real data signal.
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/rxdItu104
This attribute displays the status (on / off) of the receive data signal (circuit 104). The rxdItu104 attribute
only indicates the presence of the RxD signal, it does not monitor the real data signal.
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/rtsItu105
This attribute displays the status (on / off) of the request to send signal (circuit 105).
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/ctsItu106
This attribute displays the status (on / off) of the clear to send signal (circuit 106).
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/dsrItu107
This attribute displays the status (on / off) of the data set ready signal (circuit 107).
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/dcdItu109
This attribute displays the status (on / off) of the data carrier detect signal (circuit 109).
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/rdlItu140
This attribute displays the status (on / off) of the remote digital loop signal (circuit 140).
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/alItu141
This attribute displays the status (on / off) of the analogue loop signal (circuit 141).
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/tiItu142
This attribute displays the status (on / off) of the test indication signal (circuit 142).