Configuration attributes Crocus CNV
84 Reference manual
crocusIfConv<2m/Nx64><Tt/Cv>/Cold Boot
This action will reboot the Crocus CNV while the power stays up (the Crocus CNV also reboots if it is
powered down and up again).
This implies that:
it checks which firmware to use
it reads the saved configuration and restarts program execution.
You can use this action, for instance, to activate new firmware.
To perform a cold boot, proceed as follows:
Step Action
1
In the TMA window, select the top object crocusIfConv<2m/Nx64><Tt/Cv> and the group
Configuration, Status, Performance or Alarms.
2
In the action window of TMA, click the left mouse button on Cold Boot so that this action is
selected.
3 Press the right mouse button and select Execute.
The session between TMA and the Crocus CNV is interrupted.
4 Re-establish a TMA session on the Crocus CNV.
The Crocus CNV attributes reappear on your screen.
If a Cold Boot is performed on a Crocus CNV CV, both converter A and B reboot.