Hardware and Software Requirements
Specification Operation Storage
Temperature
†
5°C to 35°C (-23°C to 95°F), noncondensing -40°C to 65°C (-40°F to 149°F),
noncondensing
Humidity 10% to 90% noncondensing relative humidity at
27°C (80.6°F) maximum wet bulb
93% noncondensing relative humidity at
38°C (100.4°F) maximum wet bulb
Altitude 3000 meters (9842.5) at 35°C (95°F) ambient
1,219 meters (4,000 feet) at 35°C (95°F) ambient
12,000 meters (39,370 feet)
Vibration 0.15 G z-axis; 0.10 G in x- and y-axes (5-500 Hz
sine)
0.50 G z-axis; 0.25 G x- and y-axes (5-
500 Hz sine)
Shock 3 G, 11 msec half-sine 1 inch roll-off front to back, 20 mm step-
up
Threshold testing of castors at 0.75 m/s
Airflow 400 LFM at 55°C (131°F) local ambient temperature
†
Temperature listed is for the server that the card is installed in. The actual internal ambient inside the server local to the card might be higher.
Related Information
■
“Physical Specifications” on page 21
■
“Electrical Specifications” on page 22
■