Environmental Specifications
Environmental Specifications
This topic includes these specifications that apply to both server configurations:
Temperature, humidity, and elevation
Shock and vibration
Acoustic
TABLE 1
Temperature, Humidity, and Elevation Specifications
Operating NonoperatingDescription
U.S. Metric U.S. Metric
Notes
Temperature
(maximum)
41 to 95°F
at 0 to 3000 ft
5 to 35°C
at 900m
-40 to 149°F at 0
to 3000 ft
-40 to 65°C at
900m
Decrease in maximum temperature:
above 3000 ft. (900m), 1.8°F/1000 ft
(1°C/300m)
Relative humidity 10 to 90%
at 81°F
10 to 90%
at 27°C
Up to 93%
at 100°F
Up to 93%
at 38°C
Maximum wet bulb noncondensing
Altitude 0 to 9840 ft
0 m to 3000m
Up to 39,370 ft Up to 12,000m
Except in China markets where regulations might limit installations to a maximum altitude of 2km.
TABLE 2
Shock and Vibration Specifications
Description Operating Notes
Shock 3G, 11 ms Half-sine
Vibration (vertical) 0.15G 5 to 500 HZ swept-sine
Vibration (horizontal) 0.10G
TABLE 3
Acoustic Specifications
Description MIN FAN SPEED MAX FAN SPEED
Sound Power Level - LwAd (1 B = 10 dB) 7.7 B 8.9 B
Sound Pressure Level - LpAm (energy average of
4 bystander positions )
67.8 dB 80.4 dB
Related Information
SPARC T7-2 Server Safety and Compliance Guide
“Physical Specifications” on page 15
“Electrical Specifications” on page 16
“Environmental Specifications” on page 17
Confirming Specifications 17

Table of Contents

Other manuals for Oracle SPARC T7-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle SPARC T7-2 and is the answer not in the manual?

Oracle SPARC T7-2 Specifications

General IconGeneral
BrandOracle
ModelSPARC T7-2
CategoryServer
LanguageEnglish

Related product manuals