26
Connection
DIR output
This is a signal to output information of the motor rotation direction.
The DIR output is turned ON when the motor rotates in the direction to which the positive side was set in the "Motor
rotation direction" parameter.
The ON state will be continued until the motor will reversely rotates.
Related parameters
Parameter name Description Setting range Factory setting
Motor rotation direction
Sets the motor rotation direction.
(Sets the rotation direction when turning the FWD input ON if
the "2-wire mode" is selected with the "Operation input mode
selection" parameter.
Sets the rotation direction when turning the FWD/REV input
ON if the "3-wire mode" is selected.)
+=CCW
+=CW
+=CW
Example: When the "Motor rotation direction" parameter is set to "+=CW"
Motor movement
CW CW
CCW CCW
DIR putput
ON
OFF
∗∗
*
A state just before stopping is output while the motor stops.
MOVE output
The MOVE output is turned ON while the motor rotates by turning the operation input signal ON.
Motor movement
CW
Operation signal input
OFF
ON
MOVE output
ON
OFF
INFO output
If any of information is generated, the INFO output will be turned ON.
You can select whether the INFO output is applied for each information.