27
Connection
VA output
When the detected speed reached the "plus or minus range of VA detection width with respect to the setting speed,"
this output is turned ON.
A range to turn the VA output ON can be set using the "VA detection width" parameter.
Related parameters
Parameter name Description Setting range Factory setting
VA detection width Sets the detection width for the VA output. 1 to 400 [r/min] 200
Example: When the motor speed changes from the setting speed 1 to the setting speed 2
“VA detection width”
1
2
Motor speed
ON
VA output
“VA detection width”
“VA detection width”
Information bit output
If corresponding information is generated, each output signal is turned ON.
Information
Information bit
output signal
Information
Information bit
output signal
Driver temperature INFO-DRVTMP Torque limiting value setting error INFO-TRQ-DE
Overvoltage INFO-OVOLT Rotation speed setting error INFO-SPD-DE
Undervoltage INFO-UVOLT Main power supply time INFO-PTIME
Load INFO-LOAD Main power supply count INFO-PCOUNT
Speed INFO-SPD Operation start limit mode INFO-DSLMTD
Operation data setting error INFO-SET-E I/O test mode INFO-IOTEST
Operation prohibited INFO-DRV Conguration request INFO-CFG
Tripmeter INFO-TRIP Power cycling request INFO-RBT
Odometer INFO-ODO