4.
Enter the required information in the fields provided.
SNMP User Names and passwords are independent of users that are con-
figured on the Tools/Users page.
User names are arbitrary. SNMP User Names should be between 1 and
31 characters in length.
The User Name must be the same on VersaSync and on the man-
agement station.
The Auth Type field provides a choice between MD5 and SHA.
The Auth Password must be between 8 and 32 characters in length.
The Priv Type field provides a choice between AES and DES.
The Priv Passphrase must be between 8 and 32 characters in length.
The Permissions field provides a choice between Read/Write and Read
Only.
5.
Click Submit. The created user will appear in the SNMP V3 panel:
Editing and Deleting Users
To edit or delete a user you have created:
1.
Navigate to MANAGEMENT > NETWORK: SNMP Setup.
2.
Click the row of the SNMP V3 panel that displays the community you wish to edit or
delete. The cursor will change from an arrow icon to a pointing finger to indicate that
the entry is clickable.
3.
The SNMP V3 Settings window will display:
2.8 Configuring Network Settings
CHAPTER 2 • VersaSync User Manual Rev. 7.0