Saving and Downloading the Oscillator Log
The oscillator status log captures oscillator performance data, such as frequency error and
phase error. The data can be retrieved as a comma-separated .csv file that can be read and
edited with a spreadsheet software, such as Microsoft Excel
®
. You may want to review
and/or keep this data for your own records, or you may be asked by Orolia Technical Sup-
port to download and send the oscillator status log in the event of technical problems.
To download the oscillator status log:
1.
Navigate to MANAGEMENT > OTHER: Disciplining.
2.
Click on the ARROW icon in the top-right corner of the screen. Save the .csvfile to
your computer.
3.
If so asked by Spectracom Technical Support, attach the oscillator status log file (typ-
ically together with the bundled VersaSync log files, see: "Saving and Downloading
Logs" on the previous page) to your email addressed to Orolia Technical Support.
4.6.2.5 Setting up a Remote Log Server
Storing log files on a remote log server supports advanced logging functionality.
Adding a remote log server:
1.
Navigate to MANAGEMENT > OTHER: Log Configuration.
2.
In the Remote Log Server panel, click on the PLUS icon in the top-right corner of
the panel. The Add Remote Log Servers window displays.
250
CHAPTER 4 • VersaSync User Manual Rev. 7.0
4.6 Quality Management