EasyManua.ls Logo

Orolia VersaSync

Orolia VersaSync
378 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.
Click Submit.
Resetting Reference Priorities to Factory Defaults
To reset all references in the Reference Priority table to their factory default priorities:
1.
Navigate to the Configure Reference Priorities screen via MANAGEMENT >
OTHER: Reference Priority menu.
2.
In the Actions panel, click the Restore Factory Defaults button.
3.3.1.2 The "Local System" Reference
The Local System reference is a "Self" reference, i.e. VersaSync uses itself as an input ref-
erence for Time, or as a 1PPS reference. The Local System is a unique input reference in
that it can be used as either the Time reference, or the 1PPS reference, but never both.
Note: For VersaSync to operate as a Local System reference, you must
have either a valid external Time reference, or a valid external 1PPS ref-
erence.
3.3 Managing References
CHAPTER 3 VersaSync User Manual Rev. 7.0
157

Table of Contents

Other manuals for Orolia VersaSync