To confirm that BroadShield has been activated on your VersaSync unit, navigate to
TOOLS: SYSTEM > Upgrade/Backup. The center panel System Configuration will list
the Options installed in your unit.
Enabling/Disabling the BroadShield Service
The Broadshield service can be run in two operating modes:
BroadShield only: In the event jamming or spoofing is detected, VersaSync will
emit a Major Alarm, however it will continue to consider the GNSS reference as
valid, i.e. it will NOT go out of sync.
Auto Sync Control: In the event jamming or spoofing is detected, VersaSync will
emit a Major Alarm AND it will go into Holdover mode.
To configure these settings:
1.
Navigate to MANAGEMENT > Broadshield.
2.
In the BroadShield Service panel on the left, configure the desired setting:
Note: Turning BroadShield OFF and Auto Sync Control ON is an
invalid setting and will cause a "Failed to connect to the unit..." error.
3.
In the BroadShield Web UI on the right, navigate to SETTINGS > ALGORITHMS,
and ensure that Jamming and/or Spoofing detection are enabled.
Configuring BroadShield
To configure BroadShield:
1.
Navigate to MANAGEMENT > Broadshield. (If you cannot see the
Broadshieldscreen, this license is not present.) The embedded Broadshield Web UI
will open.
2.
Click SETTINGS to open the following sub-menus:
3.3 Managing References