CV GATE STATUS
The CVs and Gates status is represented in the grid in real time.
When any CV out has a positive or negative voltage (different than 0), the corresponding column will
be illuminated in blue or red color respectively.
When any Gate is active, its column will be lit in blue color.
MIDI to CV conversion
OXI One does MIDI to CV conversion from external MIDI being TRS, USB or Bluetooth.
To do so, just configure the MIDI channel of the Sequencer routed to the CV and Gate outputs you
want to use.
OXI One can currently convert Note On, Note Off and Pitch Bend messages to CV. For this purpose
you need to assign one or more CVs to pitch, allowing you to play polyphonically.
CVs and gates come calibrated, but if you need to recalibrate, please follow the instructions on
Calibration.
CV INPUT
Double tap the MOD button to enter the MOD CV IN menu. It is explained in its corresponding
section.
ANALOG CLOCK
OXI One reads and outputs MIDI clock according to a 24 ppq timing. The analog clock input and
output resolutions, as well as the Start-Stop/Reset behavior can be changed on Configuration.