Value Range Max. 32 characters
Default Value _sip._tcp.
Web User Interface Reference SRV lookup Prefix for TCP
REG_EXPIRE_TIME_n
Parameter Name Example REG_EXPIRE_TIME_1, REG_EXPIRE_TIME_2, …,
REG_EXPIRE_TIME_16
Value Format INTEGER
Description Specifies the length of time, in seconds, that the registration remains
valid. This value is set in the "Expires" header of the REGISTER
request.
Value Range 1–4294967295
Default Value 3600
Web User Interface Reference REGISTER Expires Timer
REG_INTERVAL_RATE_n
Parameter Name Example REG_INTERVAL_RATE_1, REG_INTERVAL_RATE_2, …,
REG_INTERVAL_RATE_16
Value Format INTEGER
Description Specifies the percentage of the "expires" value after which to refresh
registration by sending a new REGISTER message in the same
dialog.
Value Range 1–100
Default Value 50
REG_RTX_INTVL_n
Parameter Name Example REG_RTX_INTVL_1, REG_RTX_INTVL_2, …, REG_RTX_INTVL_16
Value Format INTEGER
Description Specifies the interval, in seconds, between transmissions of the
REGISTER request when a registration results in failure (server no
reply or error reply).
Value Range 1–86400
Default Value 10
USE_DEL_REG_OPEN_n
Parameter Name Example USE_DEL_REG_OPEN_1, USE_DEL_REG_OPEN_2, …,
USE_DEL_REG_OPEN_16
Value Format BOOLEAN
Description Specifies whether to enable cancelation before registration when, for
example, the unit is turned on.
5.3.22 SIP Settings