Value Range
• Y (Terminate)
• N (EFA)
Default Value
Y
FLASHHOOK_CONTENT_TYPE
Value Format STRING
Description Specifies the type of signal sent when sending a flash hook event.
Value Range
• Signal
• flashhook
Default Value
Signal
NUM_PLAN_PARKING
Value Format STRING
Description Specifies the call parking number.
Value Range 0–4 digits (0–9,*, #)
Default Value Empty string
Web User Interface Reference Call Park Number
CALLPARK_KEY_ENABLE
Value Format BOOLEAN
Description Specifies whether to display "Call Park" in the Call Parking Func
menu.
Value Range
• Y: Enable
• N: Disable
Default Value
N
Web User Interface Reference Enable Call Park Key
NUM_PLAN_PARK_RETRIEVING
Value Format STRING
Description Specifies the park retrieve number.
Value Range 0–4 digits (0–9,*, #)
Default Value Empty string
Web User Interface Reference Park Retrieve Number
HOLD_RECALL_TIM
Value Format INTEGER
Description Specifies the duration of the hold recall timer. If set to "0", the function
is disabled.
Value Range 0–240 (0: Disable)
5.3.30 Telephone Settings
Document Version 2016-05 Administrator Guide 267