1.18.1 Caller ID
Caller ID Signal Type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Specifies the type of signal modulation to be used when sending Caller ID information to an SLT (reference
only).
Value Range
FSK
Maintenance Console Location
4.18 [2-10] Extension CID Settings
Programming Manual References
None
Feature Guide References
1.18.1 Caller ID
Additional Local Trunk Access Code to Extension Caller ID
Enables the
PBX to automatically add a Trunk Access number to the received telephone number when sending
the Caller ID number of an incoming trunk call to an SLT.
Value Range
Disable, Enable
Maintenance Console Location
4.18 [2-10] Extension CID Settings
Programming Manual References
None
Feature Guide References
1.18.1 Caller ID
Send Caller ID Date & Time to Extension
Enables the
PBX to send the date and time of an incoming call when sending Caller ID information to an SLT.
Value Range
Disable, Enable