2.3.4 Quick Setup
Description
It is possible to set up the basic PBX parameters using a PC. When a PC accesses the PBX for the first time
with the Installer Level Programmer Code (® 2.3.1 PC Programming), Quick Setup display will appear
automatically. The following items can be programmed as desired:
Item
Parameter Description
Date & Time Year/Month/Date/
Hour/Minute
The date and time set on the PC will be used.
System Password 4–10 characters
Enter the system password for installer (®
2.3.3 Password Security).
Operator & Manager Extension Number Assign the PBX operator to all time modes (day/lunch/
break/night) (® 2.2.5 Operator Features). The extension
assigned as the PBX operators is automatically allowed
to perform manager operation (® 2.2.6 Manager
Features).
Flexible Numbering
Feature
1. Type 1
(with )
2. Type 2
(without )
If "Type 1 (with )" is selected, " " must prefix all feature
numbers (except access numbers) when an extension
user wants to use a feature.
[Example] Call Pickup feature number
Type 1 (with ): 41
Type 2 (without ): 41
For default of the flexible numbers, refer to the [Flexible
Numbering Table (available while a dial tone is heard)]
(® 2.3.6 Flexible Numbering/Fixed Numbering).
Extension From 101/from 201 Determines the number from which default extension
numbers begin.
Operator 0/9 The feature number for Operator Call can be selected.
CO Access 0/1/9 The feature number for Idle Line Access can be selected.
CO Dialling Mode Pulse/DTMF Selects the type of signal used to dial out to the analogue
trunk through LCOT/CLCOT cards.
Note that the programmable items may vary depending on the version of Maintenance Console being used.
Feature Guide 393