Parameter Usage
Light Pattern
Red on Off
(All) Used to log in to or out of all
incoming call distribution
groups to which the extension
user belongs.
After Log-out
Operation
After Log-in
Operation
If an ICD Group button is assigned, it also shows the log-in/log-out status of the corresponding group.
The light pattern is the same as the Log-in/Log-out button that includes the group number.
Wrap-up Timer
Two wrap-up timers can be programmed, an ICD Group member wrap-up timer and an extension
wrap-up timer. System programming selects which timer is used. When the ICD Group member
wrap-up timer is selected, the timer is only activated after calls to the extension through an ICD Group.
When the extension wrap-up timer is selected, the timer is activated after all calls to or from the
extension, including a retrieved call on hold.
Only calls from ICD Groups cannot be received during the wrap-up time. Other calls are received as
normal.
The wrap-up timer does not work for ISDN extensions or PS Ring Groups.
Wrap-up Button
A flexible button can be customised as the Wrap-up button. It shows the current status as follows:
Light pattern
Status
Slow red flashing Wrap-up
Red on Not Ready
Off Ready (Wrap-up mode cancel)
When a PS in Wireless XDP Parallel Mode completes a call, neither the PS nor its wired telephone can
have Wrap-up time. (® 1.25.5 Wireless XDP Parallel Mode)
Automatic Log-out
A member extension may be logged out automatically, if the Unanswered time expires a preprogrammed
number of times consecutively. The number of consecutive unanswered calls can be assigned for each
incoming call distribution group. If the extension is a member of more than one incoming call distribution
group, the unanswered number is counted across all corresponding incoming call distribution groups. It is
possible to return to log-in mode manually.
The Automatic Log-out feature does not work for extensions in an incoming call distribution group using
the Ring distribution method (® 1.2.2.2 Group Call Distribution).
Log-in/Log-out Monitor
The supervisor extension can monitor and control the log-in/log-out status of the incoming call distribution
group members. (® 1.2.2.8 Supervisory Feature)
Log-in/Log-out Information on SMDR
Log-in/Log-out information can be printed out on SMDR. (® 1.26.1 Station Message Detail Recording
(SMDR))
PC Programming Manual References
4.8 [2-6-1] Numbering Plan—Main—Features
Log-in / Log-out
Not Ready (Manual Wrap-up) Mode On / Off
5.13 [3-5-1] Incoming Call Distribution Group—Group Settings—Miscellaneous
62 Feature Guide
1.2.2 Incoming Call Distribution Group Features

Table of Contents

Other manuals for Panasonic KX-TDA100D

Related product manuals