1.11 Conversation Features
172 Feature Guide
1.11.10 Calling Party Control (CPC) Signal Detection
Description
The Calling Party Control (CPC) signal is an on-hook indication (disconnect signal) sent from the analogue
trunk when the other party hangs up. To maintain efficient utilisation of trunks, the PBX monitors their state
and when CPC signal is detected from a line, disconnects the line and alerts the extension with a reorder
tone.
Conditions
• CPC signal detection is programmable for incoming trunk calls, and for outgoing trunk calls.
• If your telephone company sends other signals similar to CPC, it is recommended not to enable CPC
signal detection on outgoing trunk calls.
• If a CPC signal is detected during a Conference call (→ 1.14.1.2 Conference), that line is disconnected,
but the remaining parties stay connected.
• If a CPC signal is detected during a call between a caller using the DISA feature (→ 1.17.6 Direct
Inward System Access (DISA)) and an extension or an outside party, the line is disconnected.
Programming Manual References
PC Programming Manual
2.7.11 [1-1] Slot—LCO Port—CPC Signal Detection Time—Outgoing, Incoming
2.7.19 [1-1] Slot—T1 Port (KX-TDA100/KX-TDA200/KX-TDA600 only)
→ CPC Signal Detection (DDI/DID)—Outgoing, Incoming (for DDI/DID channel)
→ CPC Signal Detection (LCO/GCO)—Outgoing, Incoming (for GCOT or LCOT channel)
2.7.25 [1-1] Slot—E1 Port—CPC Detection Time—Out, In
2.7.31 [1-1] Slot—DID Port—CPC Detection Time—Out (DID), In (DID)