3-level Teaching
This is a method of setting the ON and OFF range by
three levels (P-1, P-2, P-3) teaching and set the OFF
level or ON level at the middle of ‘A’ and ‘B’ (1_SL) and
set the ON level or OFF level at the middle of ‘B’ and
‘C’ (2_SL).
After teaching, P-1, P-2 and P-3 are automatically
assigned in ascending order to ‘A’, ‘B’, and ‘C’.
Time
A
1_SL
2_SL
B
C
0
ON
OFF
Incident light intensity
9,999
Output
(L-ON)
Press the
MODE key once.
Blinking by turns.
Press the
Jog switch.
Incident light
intensity for P-1.
Press the
Jog switch.
Incident light
intensity for P-2.
The status condition (A) when incident light
is the lowest intensity.
The status condition (B) when the incident light
intensity is between lowest and greatest.
1Select ‘TEACH mode’ by pressing the [MODE key] once.
2The current teaching method (green) and incident light
intensity (red) will be displayed and the amplifier will enter
the ‘P-1’ setting state.
3If the [Jog switch] is pressed while in the status condition (A)
when the incident light is the lowest intensity, then the
display will blink the incident light intensity reading (red).
4The amplifier has entered the ‘P-2’ setting state and ‘ ’
(green) will blink.
5If the [Jog switch] is pressed while in the status condition (B)
when the incident light intensity is between lowest and
greatest, the display will blink the incident light intensity
reading (red).