146
SV.PrNo.
10
11
12
13
14
18
19
1A
1B
1C
20
Title
1st position loop gain
1st velocity loop gain
1st velocity loop integration time constant
1st speed detection filter
1st torque filter time constant
2nd position loop gain
2nd velocity loop gain
2nd velocity loop integration time constant
2nd speed detection filter
2nd torque filter time constant
Inertia ratio
SV.PrNo.
15
16
27
30
31
32
33
34
35
300
50
0
1
10
30
50
33
20
Title
Setup
value
Velocity feed forward
Feed forward filter time constant
Velocity observer
2nd gain action set up
1st control switching mode
1st control switching delay time
1st control switching level
1st control switching hysteresis
Position loop gain switching time
Real-Time Auto-Gain Tuning Mode
Parameters Which Are Automatically Set
Following parameters are automatically adjusted.
Also following parameters are automatically set up.
<Notes>
When the real-time auto-gain tuning is valid, you cannot change the parameters which are automati-
cally adjusted.
SV.Pr31 becomes 10 at position or full closed control and when SV.Pr21 (Real time auto tuning set up)
is 1 to 6, and becomes 0 in other cases.