17
7.3. Error Code Table
Self-Diagnosis Function provides information on any problems occuring for the unit and its respective components by displaying
error codes. Thesed error code such as U**, H** and F** are stored in memory and held unless it is cleared.
The error code is automatically display after entering into self-diagnostic mode.
Error Code Diagnosis Contents Description of error Automatic FL Display Remarks
CD H15 CD Open Abnormal During operation
POS_SW_R On fail to be
detected with 3 sec. Error
No. shall be clear by force
or during cold start.
For CD Mechanism Unit
Press [Q] on main unit for
next error.
CD H16 CD Closing Abnormal During operation
POS_SW_CEN On fail to
be detected with 3 sec.
Error No. shall be clear by
force or during cold start.
For CD Mechanism Unit
Press [Q] on main unit for
next error.
IPD H15 iPod Open Abnormal During operation
POS_SW_L On fail to be
detected with 3 sec. Error
No. shall be clear by force
or during cold start.
For iPod
Press [Q] on main unit for
next error.
IPD H16 iPod Closing Abnormal During operation
POS_SW_CEN On fail to
be detected with 3 sec.
Error No. shall be clear by
force or during cold start.
For iPod
Press [Q] on main unit for
next error.
F15 CD REST SW Abnormal CD traverse position intial
setting operation failsafe
counter (10 s) waiting for
REST SW to turn on. Error
No. shall be clear by force
or during cold start.
For CD Mechanism Unit
Press [Q] on main unit for
next error.
F26 Communication between
CD servo LSI and micro-p
abnormal.
During switch to CD func-
tion, if SENSE = “L” within
failsafe time of 20ms.
For CD Mechanism Unit
Press [Q] on main unit for
next error.
F61/F76 Power Amp IC output
abnormal
During power-on, PDET1,
PDET2 & MAINV_DET /
TEMP_DET is “L” after 1
sec.
For power.
Press [Q] on main unit for
next error.