8.2. Initialization Pulse Adjust
1. Input a white signal to plasma video input.
2. Set the picture adjustment items as follows.
·
Picture menu : Standard
·
Color temperature : Normal
·
Picture : 25
·
Aspect : Full
3. Connect Oscilloscope to TPSC1 (T2) and adjust VR6602 for 195 ± 10µ Sec.
Test point Volume Level
T2 TPSS1 (SS) VR6602(SC) 195 ± 10µ Sec
8.3. P.C.B. (Printed Circuit Board) Remove
8.3.1. Caution
1. To remove P.C.B. , wait 1 minute after power was off for discharge from electrolysis capacitors.
8.3.2. Quick adjustment after P.C.B. Remove
P.C.B. Name Test Point Voltage Volume Remarks
P Board Vsus TPVSUS Vsus ± 2V VR251 (P) *
SC Board Vad TPVAD -105V ± 1V VR6600 (SC)
Vscn TPVSCN Vad+ 140V ± 4V Fixed
Vset TPVSET 280V ± 7V Fixed
SS Board Ve TPVE Ve ± 1V VR6000 (SS) *
Vda TPVDA 75V ± 1V Fixed
D, J Board White blance, Pedestal and Sub brightness for NTSC, PAL, HD, PC and 625i signals
DA Board Set Market Select Nomber to correct destination by Ms mode (See chap. 9.1.4)
*See the Panel label.
Caution:
Absolutely do not reduce Vsus below Ve not to damage the P.C.B.
24
TH-50PH9UK