139
• The toner cartridge is damaged.
The print quality test page does
not meet any of the following
measurements:
Cartridge:
• 25.70mm
• 35.30mm
• 75.6mm
• 26.7mm
Fuser:
• 56.5mm
Transfer module:
• 25.10mm
• 59.70mm
• 28.30mm
• 65mm
• 65mm
• It is recommended to replace with the
original toner cartridge.
• Please record the data and contact the
customer service center.
• The faults above can be mitigated by cleaning or replacing the cartridge. If the problem
persists, please contact the customer service center. See the Three Guarantees
certificate for contact details.
• Toner cartridge is not installed
properly.
• Pull out the toner cartridge tray, remove the
toner cartridge, then insert the toner
cartridge, and insert the toner cartridge tray.
• The print media does not meet the
usage specification. For example,
the print media is textured, damp, or
too rough.
• Toner cartridge is not installed
properly.
• Please correctly use the medium
conforming to the specifications. See
Section 2.
• Pull out the toner cartridge tray, remove the
toner cartridge, then insert the toner
cartridge, and insert the toner cartridge tray.