12 User’s Manual
5.7 USER OPTIONS
Options [1] and [2]: Ma ster  Featur e
Wh en  option  [1] is OFF, the User canno t pro gram other Users into the system. 
Wh en  option  [1] is ON an d option [2] is OFF, the User ca n progr am a nd modify User Access Codes (P.I.N. only) and
User La bels. 
Wh en both op tions [1] and [2] are ON, the User has Full Master rig hts. Th e User can cre ate or modify User Access
Codes, User Option s, User  Access Control Options, Access Card Numbers, User La bels and Are a Assignments
according to their own programmin g. For exampl e, if the Full Master User has acce ss to a rea #1  and option [4]
(Bypass) only, the  Full Master  User can only assign area  #1 and option [4] to other Users in the system. 
Option [3]: Duress 
Wh en op tio n [3 ] is ON, the Duress feature is en able d. Thi s feature  is used when some one forces a User to ar m o r
disarm  an  area(s). By e ntering  a   User  A ccess  Code (P.I.N.) reserved  fo r the  Du ress fea ture, the  system will arm or
disarm the  area(s), and then  send a silent alarm to the Central Mon itoring Statio n. 
Option [4]: Bypass
Wh en option [4] is ON, the  Bypass feature  is e nable d. This fea tur e a llows the User to deactivate zones when arming
the ar ea(s).
Option [5]: Arm Only 
Wh en option [5] is ON, the Ar m On ly feature is enable d. The User can arm assigned ar eas with either a card or
code, bu t cann ot di sarm. When  the  op tion is OFF, the User  can  either arm or  d isarm a ssigned areas.
Option [6]: Stay &  Instant Arm 
Wh en op tio n [6 ] is ON, the Stay and  Instant Arm features are  enab led. The User can now Stay or Instant Ar m their
assigned areas.
Option [7]: Force Arm 
Wh en  option  [7] is ON, the  For ce arm feature  is enabled. The User can  now Force a rm their assigned areas.
Option [8]: Area Access 
Wh en  option  [8] is ON, the keyp ad will p ermit access to all the areas assigned  to the User Access Code. When
option [8] is OFF, the keypad will  only permit access to the areas it controls. For example, the keypad  is assigned
area 1 only, and your  Use r Access Cod e i s  assigned  ar eas 1 to  8. If th e o ption  is ON, you  can  access all  eig ht areas
from  the  keypad.  If the  o ption is O FF, you can  o nly a ccess  area  1. 
By defa ult all Users can Regular arm the system.
5.8 ACCESS CONTROL USER OPTIONS
Option [1]: Access Card is Activated
Wh en option [1] is ON, the  Access Control Card  is activated and can b e u se d whe n A ccess Control is  enabled  in  the
system. When the optio n is OFF, the Access Con trol Card cannot be used .
Option [2]: Can Disarm with Access  Card
Wh en  option  [2] is ON, a User’s Access Control Card can unlock and disarm an armed Access Control Door. When
o pt ion [2 ] is OFF, follow th e settings in option [8] on page 13.
For option [2] to function in the ON position, option [5] “Arm Only” in the User Options must
be disabled (refer to section 5.7 on page 12).
Option [3]: Ca rd with Extend ed Unlocked Pe riod
Wh en op tion [3] is ON, “E xtended Unlocked Pe riod ” is enab led. “Extend ed Unl ocke d Per iod” r efers to  the time
period p rogr ammed into each Access Control Door by your In stalle r that extends the unlocked time  of th e doo r. For
example, if your Installer  sets the Unlocked per iod of the doo r to 30  seconds and  the  Exten ded Unlo cke d Perio d to
15 seco nds, a User  Access Code with “Extende d Unlocked Period” enabled will ha ve a  total of 45 seconds to pass
thro ugh  the door.