EasyManua.ls Logo

Parker G1 - Especificación Técnica

Parker G1
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
G1 - G9
84
2.1 Especificación técnica
Nitrógeno N
2
Modelos
Salida de
presión
bar g
Caudal
L/min
Pureza en %
de O
2
Conexiones
BSP
Entrada de
aire
(Opc. 0)
Gas
Salida
G1
0
5
0,55 10 ppm
1/4" 1/8"
1 0,75 10 ppm
G2
0
5
1,5 10 ppm
1/4" 1/4"
1 3,0 10 ppm
G3
0
5
2,5 100 ppm
1/4" 1/4"
1 4,0 0,1
2 5,0 0,5
3 7,0 1
4 8,0 2
G4
0
5
5,0 100 ppm
1/4" 1/4"
1 6,0 0,1
2 10,0 0,5
3 12,5 1
4 14,0 2
5
7
12,0 0,5
1/4" 1/4"
6 18,0 0,5
7 20,0 1
8 25,0 1
Cero N
2
G5 0 5 1,0 10 ppm 1/4" 1/8"
N
2
& Aire seco
G6 0 5
N2: 0,6 10 ppm
1/4" 1/8"
Aire: 1,5 -55pC adp
G7 0 5
N2: 3,0 10 ppm
1/4" 1/4"
Aire: 3,0 -55pC adp
Aire seco
G6 0 5 3,0 -55pC adp 1/4" 1/8"
G9 0 5 6,0 -55pC adp 1/4" 1/8"
Descripción Unidades
Calidad el aire de entrada ISO 8573.1:2001, Clase 2.-.1
Presión máxima de funcionamiento bar (psi) 10 (145)
Tensión de entrada V ac 120/230 V ac 50/60 Hz ± 10%
Temperatura °C (°F) 5 - 45 (41 - 113)
Altitud m (ft) <2000 (6562)
Grado de polución 2
Categoría de instalación II
Humedad 50% @ 40 °C (80% MÁX 31 °C)
Índice IP IP20 / NEMA 1

Table of Contents