EasyManua.ls Logo

Parker G1 - Economy Mode (Optional); Rapid Cycle

Parker G1
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
G1 - G9
12
4.3 Economy Mode (Optional)
Economy mode is the function whereby the generator will detect and monitor any back pressure from the application. If the pressure
exceeds a limit for a preset time (i.e. the application requires no gas) the generator will stop cycling and turn off all valves.
When the application requires gas, the back pressure
will drop and the generator will restart, defaulting into “Rapid Cycle”.
If the Economy option has been fitted it can be enabled as follows:
Ru n
St a n dby
From he “Standby menu” press [ ] and [ ] together.
E c onomy: on
The Economy option can enabled and disabled using the [ ] and [ ] keys.
Once enabled press [
] to return to the standby menu.
E c onomy
00000 00Hr s:
When the generator is running in economy mode, the menu will change from the normal
standard operating menu to the economy menu as shown.
00000 00Hr s:
Cl eaning B ed
Whilst in economy mode the generator will occasionally restart and display “Cleaning Bed”,
this will l flush the system and ensure that the
unit reaches the desired purity faster when
returned online.
4.4 Rapid Cycle
Rapid cycle is the function of flushing the system of impurities in order to allow the generator to reach desired purity faster. In this mode the
generator will not deliver gas to the application for up to 15 minutes and will activate every time the generator comes out of standby or
economy mode.
If the Rapid Cycle option has been fitted it can be enabled as follows:
Ru n
St a n dby
From he “Standby menu” press [ ] and [ ] together.
St a r t Opt i ons
R a pi d Cy c l e :on
The Rapid Cycle option can enabled and disabled using the [ ] and [ ] keys.
00000 00Hr s:
R a pi d Cy c l e
Once enabled press [ ] to return to the standby menu.
The Rapid Cycle will start when ever the gener
ator comes out of “Standby” mode or
“Economy” mode.
The menu will change as shown.
Important: The purity of the gas will deteriorate when the generator is in standb
y or economy mode. The following table gives an indication
of the length of time required for the generator to return to the specified purity following economy operation.
Time in Standby / Economy
Mode (Hours)
Time To Deliver High Purity
Gas (Minutes)
420
12 20
24 20
48 30
48+ 60

Table of Contents