Relion 1900e/2900e Manual
121 Revision 1.3
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicabil
ity
Sensor Type
Event/Rea
ding Type
Event Offset Triggers
Contrib. To
System Status
Assert
/De-
assert
Readabl
e
Value/
Offsets
Event
Data
Rearm
Stand-
by
03 - Power cycle
08 - Timer interrupt
Physical Security
(Physical Scrty)
04h
Chassis
Intrusion
is
chassis-
specific
Physical
Security
05h
Sensor
Specific
6Fh
00 - Chassis intrusion
Degraded
OK
As
and
De
Trig Offset A X
04 - LAN leash lost
FP Interrupt
(FP NMI Diag Int)
05h
Chassis -
specific
Critical
Interrupt
13h
Sensor
Specific
6Fh
00 - Front panel
NMI/diagnostic
interrupt
OK As Trig Offset A
SMI Timeout
(SMI Timeout)
06h All
SMI Timeout
F3h
Digital
Discrete
03h
01 State asserted Fatal
As
and
De
Trig Offset A
System Event Log
(System Event Log)
07h All
Event Logging
Disabled
10h
Sensor
Specific
6Fh
02 - Log area
reset/cleared
OK As Trig Offset A X
System Event
(System Event)
08h All
System Event
12h
Sensor
Specific
6Fh
04 PEF action OK As - Trig Offset A X
Button Sensor
(Button)
09h All
Button/Switch
14h
Sensor
Specific
6Fh
00 Power Button
02 Reset Button
OK AS _ Trig Offset A X
BMC Watchdog 0Ah All
Mgmt System
Health
28h
Digital
Discrete
03h
01 State Asserted Degraded As Trig Offset A -
Voltage Regulator Watchdog
(VR Watchdog)
0Bh All
Voltage
02h
Digital
Discrete
03h
01 State Asserted Fatal
As
and
De
Trig Offset M X
Fan Redundancy
(Fan Redundancy)
0Ch
Ch
assis-
specific
Fan
04h
Generic
0Bh
00 - Fully redundant
OK
As
and
De
Trig Offset A
01 - Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded

Table of Contents