Relion 1900e/2900e Manual
Revision 1.0 122
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicabil
ity
Sensor Type
Event/Rea
ding Type
Event Offset Triggers
Contrib. To
System Status
Assert
/De-
assert
Readabl
e
Value/
Offsets
Event
Data
Rearm
Stand-
by
03 - Non-redundant:
Sufficient resources.
Transition from
redundant
Degraded
04 - Non-redundant:
Sufficient resources.
Transition from
insufficient.
Degraded
05 - Non-redundant:
insufficient resources.
Non-Fatal
06 Non-Redundant:
degraded from fully
redundant.
Degraded
07 - Redundant
degraded from non-
redundant
Degraded
SSB Thermal Trip
(SSB Therm Trip)
0Dh All
Temperature
01h
Digital
Discrete
03h
01 State Asserted Fatal
As
and
De
Trig Offset M X
IO Module Presence
(IO Mod Presence)
0Eh
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 Inserted/Present OK
As
and
De
Trig Offset M -
SAS Module Presence
(SAS Mod Presence)
0Fh
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 Inserted/Present OK
As
and
De
Trig Offset M X
BMC Firmware Health
(BMC FW Health)
10h All
Mgmt Health
28h
Sensor
Specific
6Fh
04 Sensor Failure
Degraded
As - Trig Offset A X
System Airflow
(System Airflow)
11h All
Other Units
0Bh
Threshold
01h
Analog
FW Update Status 12h All
Version Change
2Bh
OEM
defined
70h
00h Update started
01h Update
completed
successfully.
02h Update failure
OK As _ Trig Offset A _