Design specifications/ratings
Valve body Fiber-reinforced polymer
Rubber components EP/EPDM/silicone
Valve material certification DM174, ACS, EC
Weight (valve with controller) 2kg (max)
Recommended operating pressure 1.4 - 8.6bar
Maximum inlet pressure 8.6bar
Hydrostatic test pressure 20bar
Water temperature 1 - 43°C
Ambient temperature 0 - 52°C
Flow rates (3.5 bar inlet - valve only)
Continuous service flow (Δp=1bar) 4.7m
3
/h
Peak service flow (Δp=1.7bar) 6.1m
3
/h
Cv* 5.4gpm
Kv* 4.67m
3
/h
Maximum backwash flow
(Δp=1.8bar)
3.8m
3
/h
*Cv: Flow rate in gpm across the valve at a pressure drop of 1 psi at 60°F.
*Kv: Flow rate in m
3
/h across the valve at a pressure drop of 1 bar at 16°C.
Valve connections
Tank Thread 2½" - 8NPSM
Inlet/Outlet ¾" or 1"
Riser tube 26.7mm O.D., 1.05"tube
Drain line ½" O.D.
Brine line (1650) ⅜"
Electrical
Transformer input voltage 100 to 240VAC
Input supply frequency 50 to 60Hz
Transformer output voltage 12VDC
Motor input voltage 12VDC
Controller input voltage 12VDC
Controller max. power consumption 6W
Protection rating IP22