EasyManua.ls Logo

Pentair Fleck 5800 LXT - BLFC Cleaning

Pentair Fleck 5800 LXT
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer manual Fleck 5800 LXT - Maintenance
Ref. MKT-IM-005 / F - 30.04.2020 73 / 96
9.4.7 BLFC cleaning
1. Using a wrench, remove the BLFC holder (1).
2. Using pliers, remove the grid (4) from BLFC holder (1).
3. Remove the BLFC washer (3) from the grid (4).
4. Clean with a terry cloth or change the BLFC washer (3) and the seal (2).
5. Clean the grid (4).
6. Lubricate the seal (2) with approved lubricant only.
Caution - material
Risk of damage due to wrong lubricant use!
Do not use petroleum-based lubricants such as Vaseline, oils, or hydrocarbon-
basedlubricants.
Do not use silicon grease.
Use only P-80
®
Emulsion lubricant (water based lubricant)!
7. Reverse above procedure steps to rebuild.
Mandatory
The washers (3) have to be installed with their chamfered side upfront the water
stream flow.
Flow indication must be visible after the washer (3) is placed on the holder (1).