IC-KP2-2HB17-2V1D
IDENTControl Compact unit
with Ethernet interface
FACTORY AUTOMATION
MANUAL

Table of Contents

Questions and Answers

  • J
    Jeffrey MontgomeryAug 16, 2025
    Why the website cannot be displayed on Pepperl+Fuchs Control Unit?
    • T
      Travis CraigAug 16, 2025
      If the website for your Pepperl+Fuchs Control Unit cannot be displayed, it might be due to an incorrect IP address. If you're using a DHCP server, ensure the IP address in your browser matches the one assigned to the device. If you're not using a DHCP server, verify that the IP address in your browser corresponds to the fixed IP address set in the device. Also, check the subnet mask in both cases.
  • A
    Amanda RiggsAug 19, 2025
    What to do if PWR/ERR LED illuminates red on Pepperl+Fuchs IC-KP2-2HB17-2V1D Control Unit?
    • L
      Lauren KaiserAug 19, 2025
      If the PWR/ERR LED on your Pepperl+Fuchs Control Unit illuminates red during PROFINET communication, there could be two potential causes: * There might be no physical connection to the master, possibly due to a broken lead. To resolve this, check the lead and repair it if necessary. * The assigned device name might be incorrect. To fix this, configure the same device names in both the master and the device.
  • K
    Kayla SextonAug 22, 2025
    Why CHx display does not appear on Pepperl+Fuchs IC-KP2-2HB17-2V1D?
    • D
      Dr. Katherine GriffinAug 22, 2025
      If the CHx display on your Pepperl+Fuchs Control Unit doesn't appear even when the read/write head is connected to port 1, it could be due to: * A faulty or incorrectly connected lead. Check the lead and repair or reconnect it if necessary. * A faulty read/write head. Inspect the read/write head and repair or replace it if needed.
  • N
    Nancy DuffyAug 26, 2025
    How to fix Link/Act LED when it does not illuminate on Pepperl+Fuchs IC-KP2-2HB17-2V1D?
    • S
      Shannon GrahamAug 26, 2025
      If the Link/Act LED on your Pepperl+Fuchs Control Unit doesn't illuminate, it's likely due to a lack of physical network connection, possibly caused by a broken lead. Check the lead and repair it if necessary.
  • L
    Laura MartinAug 28, 2025
    Why LEDs are flashing on Pepperl+Fuchs IDENTControl display?
    • R
      russelldelgadoAug 28, 2025
      If the LEDs in the reader and the CHx display on your Pepperl+Fuchs IDENTControl display are flashing, it means that the connected reader does not support the currently set tag type. To resolve this, select a tag type that is supported by the reader.
  • G
    Garrett HerringAug 31, 2025
    Why PWR/ERR LED illuminates yellow on Pepperl+Fuchs Control Unit?
    • J
      Joe DunnAug 31, 2025
      If the PWR/ERR LED on your Pepperl+Fuchs Control Unit illuminates yellow, it indicates that the device is still booting up. Please wait until the booting process is complete.
  • T
    tstoneSep 3, 2025
    What to do if read command gives status 4 on Pepperl+Fuchs IC-KP2-2HB17-2V1D?
    • L
      Lance KirbySep 3, 2025
      If a read command (e.g., SR ...) on your Pepperl+Fuchs Control Unit gives the status 4 even with correct syntax, it's likely due to an incorrect tag type (e.g., IPC02) being set for the relevant channel. Read commands only work with read/write tags, not read-only tags. Set the correct tag type (e.g., IPC03) or use 'Autodetect' with the CT... command.
  • E
    Erica WilsonSep 6, 2025
    Why SG or EG command gives status 4 on Pepperl+Fuchs IC-KP2-2HB17-2V1D Control Unit?
    • J
      Joanna AlvarezSep 6, 2025
      If the SG or EG (get configuration) command on your Pepperl+Fuchs Control Unit gives the status 4 even when the syntax is correct, it's because IPC03 is not set for the relevant channel. The configuration commands only function if the read/write tag IPC03 is set, and not in Autodetect mode. Set the tag type IPC03 using the CT... command.
  • C
    Christina CarsonSep 9, 2025
    What does it mean if PWR/ERR LED flashes green on Pepperl+Fuchs IC-KP2-2HB17-2V1D Control Unit?
    • C
      Cristina RossSep 9, 2025
      If the PWR/ERR LED on your Pepperl+Fuchs Control Unit flashes green (for Ethernet/IP communication only), it indicates a memory overflow. Reduce the data hold time to resolve this issue.
  • B
    Brenda BrownSep 12, 2025
    How to troubleshoot PWR/ERR LED when it does not illuminate on Pepperl+Fuchs IC-KP2-2HB17-2V1D Control Unit?
    • J
      joel09Sep 12, 2025
      If the PWR/ERR LED on your Pepperl+Fuchs Control Unit does not illuminate, it indicates that the power supply is not guaranteed. Ensure the power supply using a 24 V DC source.

Summary

Introduction to IDENTControl Compact

Symbols Used in Manual

Explains the various symbols employed throughout the manual for clarity.

Contact Information

Provides contact details for Pepperl+Fuchs GmbH for inquiries.

Declaration of Conformity

CE Conformity Statement

Confirms the product's adherence to applicable European standards and guidelines.

Safety Precautions and Guidelines

Safety Symbols Explained

Details the meaning of danger, warning, and caution symbols for user safety.

Intended Use and Operation

Specifies the proper application and operational context of the device.

General Safety Notes

Outlines crucial safety precautions and responsibilities for device operation.

Electrical Shock Protection

Addresses electrical safety, particularly concerning shock hazards and grounding.

Product Description and Features

IDENTControl Product Family Overview

Introduces the IDENTControl system, its components, and integrated features.

Connection Accessories Guide

Lists and describes connection cables and accessories for system integration.

Device Interfaces and Connections

Illustrates and explains the device's physical ports and network interfaces.

Displays and Controls Overview

Describes the function and status indications of LEDs and operating controls.

Installation Procedures

Unpacking and Initial Inspection

Provides instructions for initial inspection and verification of product contents.

EMC Shielding and Interference Protection

Explains the device's electromagnetic compatibility design for noise immunity.

Device Mounting and Installation

Guides on physically mounting the device, including recommended accessories.

Electrical Connection Guide

Details the electrical connections for power, R/W heads, and trigger sensors.

Commissioning and Setup

Preliminary Commissioning Considerations

Discusses factors influencing system performance and planning for commissioning.

Device Settings and Configuration

Emphasizes the necessity of configuring device parameters before operation.

IP Address Configuration

Provides step-by-step instructions for configuring the network IP address.

Commands and Communication Protocols

Command Types Overview

Differentiates between single mode and enhanced mode command operations.

Web Functionality Guide

Details how to use the integrated web interface for device management.

TCP;IP Communication

Covers TCP/IP data exchange, communication flow, and command structure.

MODBUS TCP;IP Communication

Explains MODBUS TCP/IP protocol, registers, and data exchange methods.

EtherNet;IP Communication

Describes data exchange, modes, and objects used in EtherNet/IP communication.

PROFINET Communication

Covers PROFINET IO concept, device types, and project planning with GSD files.

Command Overview and System Commands

Summarizes available commands, including system and standard read/write commands.

Specialized Tag Commands

Details commands for IPC03, IPC11, IDC tags, and extended command modes.

Fault and Status Message Interpretation

Explains error codes and status messages for troubleshooting identification issues.

Technical Specifications

Device Dimensions

Provides the physical dimensions and external views of the device.

Technical Data Summary

Lists comprehensive technical specifications including electrical and environmental data.

Troubleshooting Guide

Common Faults, Causes, and Remedies

A table detailing common issues, their causes, and recommended solutions.

ASCII Character Reference

ASCII Value Mapping

A reference table mapping ASCII characters to their hexadecimal and decimal values.

Appendix A: Usage Examples

Example 1: Implicit Command Usage

Demonstrates setting tag types and reading data using implicit commands on channels 1 and 2.

Example 2: Separated Mode Operations

Illustrates setting tag types, writing, and reading data using separated mode instances.

Appendix B: EtherNet;IP Object Model

EtherNet;IP Object Model Structure

Describes the structure of the EtherNet/IP object model and its classes.

Identity Object Attributes

Details the attributes and services available within the Identity object.

Assembly Object Attributes

Provides information on Assembly objects, their instances, and data mapping.

Output Command Object Details

Lists attributes and services for output command objects used in communication.

Input Command Object Details

Lists attributes and services for input command objects used in communication.

Boot-up Parameter Object Information

Details parameters related to device boot-up configuration and modes.

Diagnostics Object Attributes

Describes the attributes and services for accessing device diagnostic information.

Pepperl+Fuchs IC-KP2-2HB17-2V1D Specifications

General IconGeneral
BrandPepperl+Fuchs
ModelIC-KP2-2HB17-2V1D
CategoryControl Unit
LanguageEnglish

Related product manuals