2014-02
40
IC-KP2-2HB17-2V1D
Commands
7.8 Communication via Ethernet/IP
7.8.1 Data exchange via EtherNet/IP
EtherNet/IP is an open fieldbus standard, which enables data exchange between PLCs, PCs,
control systems, monitoring systems, sensors, and actuators.
Visit the ODVA website for information on the EtherNet/IP: www.odva.org.
Performance spectrum
Implicit message
Explicit message
PCCC
PLC settings for implicit communication
Configure the following parameters in addition to the IP address:
The lower limit of the RPI is 10 ms.
Data/Command transmission
The data is exchanged by commands that the IDENTControl Compact recognizes. Unlike
commands that are used for TCP/IP and MODBUS protocols, EtherNet/IP commands do not
have a command length parameter.
The commands are transmitted via Ethernet/IP objects, i.e. objects from classes 04h, 64h, and
65h. There are two different modes: "Mixed mode" and "Separated mode".
7.8.2 Mixed mode
Figure 7.1 1 see chapter 7.8.4
Assembly instance Size (32 bits)
Input 150 - 162 (output + 50d) 2-15*
Output 100 - 112 2-15*
Configuration 112 0
Table 7.6 * see chapter 7.8.5
channel 1
channel 2
channel
IDENTControl Compact
class 64h
instance 06 d
attribute 1-4
1
class 65h
instance 06 d
attribute 1-4
1
input command objectoutput command object

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pepperl+Fuchs IC-KP2-2HB17-2V1D and is the answer not in the manual?

Pepperl+Fuchs IC-KP2-2HB17-2V1D Specifications

General IconGeneral
BrandPepperl+Fuchs
ModelIC-KP2-2HB17-2V1D
CategoryControl Unit
LanguageEnglish

Related product manuals