The value range contains 7 characters:
the first 3 characters contain the values 0 ... F (hexadecimal code)
the last 4 characters contain the values 0 ... 9 (decimal code)
You must select the tag type '50' (ICC-...) beforehand in order to read out this code. If a "read
only code" command is executed when the tag type '50' (IDC-...-1K) is set, the 4-byte read only
code for this tag is issued.
7.15 Extended Command Modes
Extended commands for type IDC-... and IUC tags
Type IDC-...-1K tags can be programmed to read 24-bit information (so-called special read
only code) very quickly. This is useful for detecting containers in automated warehouses.
To write the special read only code use the commands SP and EP; to read it out, use the
commands SS and ES.
If SP or EP is used to write to an IDC-...-1K tag, the tag is then locked. If you wish to write to the
tag again using standard commands, unlock it using the command SI.
Length of the special read only code:
Tag of the type IDC-...-1K: 48 bit
Tag of the type IUC: 96 ... 240 bit