Commands
7.14 "Write Read Only Code" Command for Type IPC11 and IDC-...-1K
Read/Write Tags
Tags IPC11 can be programmed to behave like the IPC02 read only tag. To do this, use the
commands SX and EX. The code is read when tag type '02' or '11' is set with the commands SF
and EF.
Tags IDC-...- 1K can be programmed to behave like the ICC read only tag. This programming
occupies the first 8 bytes in the tag and occurs when the tag type '50' is set with the commands
SX or EX.
This code is read when tag type '52' is set with the commands SF or EF. If you use the
command SF or EF when tag type '50' is selected, the 4-byte read only code of the tag is
issued.
Single write fixcode (SX)
Command:
Response:
The R/W head makes only one attempt to write a read only code.
Byte Type Bit no.
7 6 5 4 3 2 1 0
Byte 0* Telegram length, high byte 0 0 0 0 0 0 0 0
Byte 1* Telegram length, low byte 0 0 0 0 1 0 1 1
Byte 2 Command code (1Fh) 0 0 0 1 1 1 1 1
Byte 3 FixLen/Channel/Toggle bit <FixLen> <Channel> <T>
Byte 4 FixType <FixType> (high byte)
Byte 5 FixType <FixType> (low byte)
Byte 6 Data 00h ... FFh <Data>
Byte 7 Data 00h ... FFh <Data>
Byte 8 Data 00h ... FFh <Data>
Byte 9 Data 00h ... FFh <Data>
Byte 10 Data 00h ... FFh <Data>
Byte Type Bit no.
7 6 5 4 3 2 1 0
Byte 0* Telegram length, high byte 0 0 0 0 0 0 0 0
Byte 1* Telegram length, low byte 0 0 0 0 0 1 1 0
Byte 2 Command code (1Fh) 0 0 0 1 1 1 1 1
Byte 3 FixLen/Channel/Toggle bit 0 1 0 1 <Channel> <T>
Byte 4 Status <Status>
Byte 5 Reply counter <ReplyCounter>
Table 7.26 * this byte is only used with the TCP/IP and MODBUS TCP/IP protocol.
IPC11: <FixLen> = 5
<FixType> = '02' ASCII (30h 32h), the read only code cannot be changed
'11' ASCII (31h 31h), the read only code can be overwritten

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pepperl+Fuchs IC-KP2-2HB17-2V1D and is the answer not in the manual?

Pepperl+Fuchs IC-KP2-2HB17-2V1D Specifications

General IconGeneral
BrandPepperl+Fuchs
ModelIC-KP2-2HB17-2V1D
CategoryControl Unit
LanguageEnglish

Related product manuals