EasyManuals Logo

Pepperl+Fuchs IC-KP2-2HB17-2V1D User Manual

Pepperl+Fuchs IC-KP2-2HB17-2V1D
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #81 background imageLoading...
Page #81 background image
IC-KP2-2HB17-2V1D
Commands
2014-02
81
Type IDC-...-1K tags can be programmed in such a way that they are compatible with the type
ICC-... read only carriers. This programming occupies the first 8 bytes in the tag. The read/write
commands can be used to access the remaining memory.
You must set the tag type '50' in order to program type IDC-...-1K tags. To do this, transmit the
command SX or EX.
The value range contains 7 characters:
the first 3 characters contain the values 0 ... F (hexadecimal code)
the last 4 characters contain the values 0 ... 9 (decimal code)
You must select the tag type '50' (ICC-...) beforehand in order to read out this code. If a "read
only code" command is executed when the tag type '50' (IDC-...-1K) is set, the 4-byte read only
code for this tag is issued.
IDC-...-1K: <FixLen> = 7
The first 3 bytes are hexadecimal (0h ... Fh), the last 4 bytes are
decimal (0d ... 9d).
<FixType> = '52' ASCII (35h 32h), the read only code can be overwritten
<Data> = (Byte 1 to 3): 0x30 ... 0x39; 0x41...0x46
(Byte 4 to 7): 0x30...0x39

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pepperl+Fuchs IC-KP2-2HB17-2V1D and is the answer not in the manual?

Pepperl+Fuchs IC-KP2-2HB17-2V1D Specifications

General IconGeneral
BrandPepperl+Fuchs
ModelIC-KP2-2HB17-2V1D
CategoryControl Unit
LanguageEnglish

Related product manuals