Table 77
Troubleshooting Test Steps
Values Results
1. Operator
A. Determine the events that caused the engine to stall.
B. Delay engine shutdown may not have completed.
Operator Result: The operator is operating the engine correctly.
Proceed to Test Step 2.
Result: The operator is not operating the engine correctly.
Repair: Make sure that the operator has the information re-
quired to operate the engine correctly.
2. Fuel
A. The engine has run out of fuel.
Fuel Result: The engine is out of fuel.
Repair: Make sure the fuel gauge is providing an accurate
reading.
Make sure that the operator knows that the engine requires
an adequate fuel supply.
Verify that the issue is eliminated.
Result: The engine is not out of fuel.
Proceed to Test Step 3.
3. Mechanical Failure
A. Check for a mechanical failure.
Mechanical
failure
Result: A mechanical failure has occurred.
Repair: Diagnose and then repair the fault.
Verify that the repair eliminated the fault.
If the fault is still present, contact the Dealer Solutions Net-
work (DSN).
i06157542
Engine Shutdown Occurs
Intermittently
Note: Use this procedure only if the engine shuts
down completely during operation.
Probable Causes
• Active codes and logged codes
• Electrical connections
• Unstable fuel supply
• Switches
• Circuit protection
• Engine speed/timing
Table 78
Associated Diagnostic Trouble Codes
J1939 Code PDL Code
3719-0 E995 (3)
3719-16 E995 (2)
5246-0 E1389 (3)
Recommended Actions
Note: The procedures have been listed in order of
probability. Complete the procedures in order.
UENR4469-36 157
Symptom Troubleshooting