Timeline For First Fault Occurrence
Table 145
World-Wide
NOx Reduction System Fault
-
Normal operation Level 1 Level 2 Level 3 Override
J1939 Code
-
5246-15 5246-16- 5246-0
-
PDL Code
-
E1389 (1) E1389 (2) E1389 (3)
-
Inducement Time
First occurrence
None 35 Hours 60 minutes Shut down or idle
Until fault heals
Cycling the keyswitch
will give 20 minutes
of full power
The system must be fault free for 40 hours before the system will reset to zero. If the fault is intermittent, and returns within the 40 hours, then
the repeat inducement time will be triggered.
The override can only be used once.
Repeat Inducement
time
None 48 minutes 60 minutes Shut down or idle
Until fault heals
Cycling the keyswitch
will give 20 minutes
of full power
Inducement None None None
Notification None Emission malfunction
lamp will be on solid
Emission malfunction
lamp will flash
Emission malfunction
lamp will flash
The stop lamp will
activate
Emission malfunction
lamp will flash
i06026810
Valve Lash Is Excessive
Probable Causes
• Lubrication
• Valve train components
Recommended Actions
Note: The procedures have been listed in order of
probability. Complete the procedures in order.
266 UENR4469-36
Symptom Troubleshooting