(Table 140, contd)
3216-12 3002-12
Aftertreatment #1 Intake NOx : Failure DEF Quality/Tampering/Dosing Interruption
3217-16
E1407 (2)
Aftertreatment #1 Intake O2 : High - moder-
ate severity (2)
DEF Quality/Tampering/Dosing Interruption
3226-5 3609-5
Aftertreatment 1 Outlet NOx : Current Below
Normal
DEF Quality/Tampering/Dosing Interruption
3226-6 3609-6
Aftertreatment 1 Outlet NOx : Current Above
Normal
DEF Quality/Tampering/Dosing Interruption
3226-7
E1432 (2)
Aftertreatment #1 Outlet NOx : Not Respond-
ing Properly
DEF Quality/Tampering/Dosing Interruption
3226-11 3609-11
Aftertreatment #1 Outlet NOx : Other Failure
Mode
DEF Quality/Tampering/Dosing Interruption
3226-12 3609-12
Aftertreatment #1 Outlet NOx : Failure DEF Quality/Tampering/Dosing Interruption
3227-16
E1408 (2)
Aftertreatment #1 Outlet O2 : High - moder-
ate severity (2)
DEF Quality/Tampering/Dosing Interruption
3242-3 2452-3
Aftertreatment #1 DPF Intake Gas Tempera-
ture : Voltage Above Normal
DEF Quality/Tampering/Dosing Interruption
3242-4 2452-4
Aftertreatment #1 DPF Intake Gas Tempera-
ture : Voltage Below Normal
DEF Quality/Tampering/Dosing Interruption
3360-3 3820-3
Catalyst Tank Controller : Voltage Above
Normal
DEF Quality/Tampering/Dosing Interruption
3360-4 3820-4
Catalyst Tank Controller : Voltage Below
Normal
DEF Quality/Tampering/Dosing Interruption
3361-5 3821-5
Catalyst Dosing Unit : Current Below Normal DEF Quality/Tampering/Dosing Interruption
3361-6 3821-6
Catalyst Dosing Unit : Current Above Normal DEF Quality/Tampering/Dosing Interruption
3361-7 3821-7
Catalyst Dosing Unit : Not Responding
Properly
DEF Quality/Tampering/Dosing Interruption
3363-5 3126-5
Catalyst Tank Heater : Current Below Normal DEF Quality/Tampering/Dosing Interruption
3363-6 3126-6
Catalyst Tank Heater : Current Above Normal DEF Quality/Tampering/Dosing Interruption
3516-2 3100-2
Aftertreatment #1 DEF Concentration : Er-
ratic, Intermittent, or Incorrect
DEF Quality/Tampering/Dosing Interruption
3516-12 3100-12
Aftertreatment #1 DEF Concentration :
Failure
DEF Quality/Tampering/Dosing Interruption
3516-18
E1364 (2)
Aftertreatment 1 Diesel Exhaust Fluid Con-
centration : Low - moderate severity (2)
DEF Quality/Tampering/Dosing Interruption
3563-3 1785-3
Engine Intake Manifold #1 Absolute Pressure
: Voltage Above Normal
DEF Quality/Tampering/Dosing Interruption
3563-4 1785-4
Engine Intake Manifold #1 Absolute Pressure
: Voltage Below Normal
DEF Quality/Tampering/Dosing Interruption
4334-3 3090-3
Aftertreatment #1 SCR Dosing Reagent Ab-
solute Pressure : Voltage Above Normal
DEF Quality/Tampering/Dosing Interruption
4334-4 3090-4
Aftertreatment #1 SCR Dosing Reagent Ab-
solute Pressure : Voltage Below Normal
DEF Quality/Tampering/Dosing Interruption
4334-16
E930 (2)
Aftertreatment #1 SCR Dosing Reagent Ab-
solute Pressure : High - moderate severity (2)
DEF Quality/Tampering/Dosing Interruption
(continued)
260 UENR4469-36
Symptom Troubleshooting