EasyManua.ls Logo

Perkins 1204-E44TA - Page 30

Perkins 1204-E44TA
524 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Illustration 23 g03747092
Typical configuration screen
1. Connect to the electronic service tool.
2. Select the Service tab.
3. Select the Configuration tab to view the
configuration parameters.
If an ECM is replaced, the appropriate parameters
must be copied from the old ECM. Copy the
parameters with the Copy Configuration feature of
the electronic service tool. The Copy Configuration
tab is below the Configuration tab. Alternatively, the
settings can be recorded on paper and then
programmed into the configuration screen for the
new module.
NOTICE
Changing the parameters during engine operation
can cause the engine to operate erratically and can
cause engine damage.
Only change the settings of the parameters when the
engine is STOPPED.
30 UENR4469-36
Configuration Parameters
Copyright of Perkins Engine Company Limited. NOT FOR REPRINTING OR RESALE

Table of Contents