EasyManua.ls Logo

Perkins 1204-E44TA - Page 374

Perkins 1204-E44TA
524 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(Table 206, contd)
411-13 3387-13
Engine Exhaust Gas Recirculation
Differential Pressure : Out of
Calibration
The ECM detects the following conditions:
The NRS differential pressure is outside the acceptable
range during initialization check, or during sensor calibra-
tion when the engine is not running.
The warning lamp will come on and the engine will be
derated.
The code is logged.
3358-13 3385-13
Engine Exhaust Gas Recirculation
Inlet Pressure : Out of Calibration
The ECM detects the following conditions:
The offset between the NRS inlet pressure and the baro-
metric pressure is outside the acceptable range during in-
itialization check.
The offset between the NRS inlet pressure and the baro-
metric pressure is outside the acceptable range during
sensor calibration when the engine is not running.
The warning lamp will come on and the engine will de-
rate. The code is logged.
3563-13 1785-13
Engine Intake Manifold #1 Absolute
Pressure : Out of Calibration
The ECM detects the following conditions:
The offset between the intake manifold air pressure and
the barometric pressure is outside the acceptable range
during initialization check.
The offset between the intake manifold air pressure and
the barometric pressure is outside the acceptable range
during sensor calibration with the engine not running.
The warning lamp will come on and the engine will
derate.
The code is logged.
374 UENR4469-36
Circuit Tests
Copyright of Perkins Engine Company Limited. NOT FOR REPRINTING OR RESALE