Illustration 182 g03422642
When this feature is installed, the number of
maintenance cycle hours can be set. The ECM then
counts down these hours and flags an Event code. A
J1939 message is sent once the cycle interval
reaches 0.
This parameter can then be reset via the electronic
service tool or over the CAN data link after the
service has been completed.
The PM1 Interval is not applicable to this engine.
Operator Inducement Emergency
Override Configuration
This feature is configurable through the main
configuration screen in the service tool. If the request
is approved by regulating agency, the SCR Operator
Inducement Emergency Override can be triggered to
remove SCR Inducements. This situation may apply
where a machine is operating in a natural disaster
zone where DEF fluid is not available.
The strategy will not allow SCR inducements during
the standard mode timer (120 hours), or the engine
run backstop timer (240 hours). The standard mode
strategy can be used multiple times until the standard
mode timer is expired or engine run backstop timer
has been reached.