Care and maintenance
10 - 4
Fig. 10 - 05
10.06 Checking and adjusting the air pressure
Before each use of the machine, check
the air pressure on gauge 1.
The gauge 1 must display a pressure of
6 bar.
If necessary, alter the pressure to this
level. To do so, lift knob 2 and turn it until
the required pressure is reached.
10.07 Emptying/cleaning the water container of the air filter/regulator
Turn the machine off.
Remove the compressed air hose
from the air filter.
Emptying the water container
The water container
11
11
1 empties itself
automatically when the compressed-air
hose is removed from the air filter/
regulator.
Cleaning the filter
Unscrew water container 1 and remove
filter 2.
Clean the filter with compressed air or
with isopropyl alcohol, part number
95-665 735-91.
Screw filter 2 back into place and screw
water container 1 back on.
Fig. 10 - 06
2
1
max.
1
2