Adjustment
11 - 24
11.05.02 Control cam (preliminary adjustment)
Requirement
1. Control cam 1, must be centred with the cutout of bearing mounting 5.
2. With the needle bar at t.d.c., screws 2 must be visible from the front and aligined
parallel with the bedplate.
Re-position control cam 1 (screws 2) and fixing collars 3 (screws 4) according to
Requirement.
2
1
5
3
4
3
4
Fig. 11 - 22